PERFORMANCE
Insulated Over Head Lines Connector
Anchor Bracket
Suspension and Anchor Clamps
Dead End Clamps
Insulated Sleeves&Lugs
Insulating Piercing Connectors
Cable Lug&Terminal
Solderless Terminal and Connector
Cable Lug
Cable Fitting
Suspension&Tension Clamps
Link Fittings
Connectors
Insulator
Porcelain Insulator
Composite Line Post Insulator
Glass Insulator
Composite Pin Insulator
Suspension Insulator
Drop Out Fuse Switch Disconnector
Disconnector Switch
Drop Out Fuse
Surge Arrestor
Cable Accessories
Heat& Cold Shrinkable Accessories
Plastic Products
Tools
Operating Tools
Electric Safety Tools
Electric Contruction Tools
Tanho Electrical Equipment Co., Ltd
Address:Changhong Industry Zone,Liushi,Zhejiang,Leqing,325604,China

Mechanical performance:

The grip force of the wire clamp is 10 bigger than the break force of the lead.t comply with GB2314-1997.

Temperature rise performance:

Under the condition of big current,the temperature rise of connector is less than thatof connection lead.

Heat circle performance:

200 times per second,100A/mm2 big current overload,the change of connection resistance is less than 5%.

Waterproof insulation performance:

Under water for 30cm,input over 3.5kV voltage for 1 min,no break out.

Resistance to corrosion performance:

Under the condition of SO2 and salt fog.it can do three times of fourteen days circle testing.

Environmental aging performance:

Under the circumstance of ultravioletradiation,dry and moist expose it with change of temperatureand heat impulse for six weeks.

Low temperature installation test:

Connector and cable cooled down in a freezeror cdimate chamber below10'C screw the nut untlcontact occurs.

Mechanical strength test of body:

Bol is tighteneduntil the nut shear of in the defned limits and the value will be recorded change theinsert in the electronically torque moment key to a bigger one ,tighten the bolt with more than 1times of the max.Torque moment the bodyshould not crack.

Arrester Routine Tests:

Physical lnspection:Every molded ubber part block.wrap module,brackets and completed unit is visually examined to reject defectiveproducts.

AC Reference Voltage Test:This test measures the voltage once a predetermined maximum peak current is reached.Partal DischargeTest: This test ensures that the partial discharge level of the arrester does not exceed a levelof 10 pC.

Residual Voltage:

Tested on individual blocks.

Arrester Type Tests:

Testing Compliant with GB/T8952-2005. lncludingInsulation withstand tests on housing Residual voltage tests Long-duration current impulse withstand Operating votage testsShort circuit current tests Internal partial discharge tests.

Higher interrupt capacities:

By using a copper arc-shortening rod attached to the dome nut inside the top of the fuse tube,lowering the fuse link, higher interrupt ratingsare obtainable.lt is necessary to use fuse links with removable button heads when using an arc-shortening rod.

Creepage distance:

Cutouts are available for use under various pollution conditions.Units are available in 245mm to 870mm,other creepage distance areavailable on request.

Extra Corrosion protection:

All cutouts are available with components made from stainless steel and plated copper ally,to offer greater corrosion resistance forseverely aggressive environments where corrosion can become a major factor.

 

Glass Insulator (Standard Profile)

Glass Insulator (Fog Profile)

Composite Pin Insulator

Gw9 Series Outdoor High Voltage Isolator Switch

Polymer Pin Insulator 36kv

Composite Insulator are made of glassfiber epoxy core rod, silicone rubber shed and metal fittings. The silicon rubber shed adopt the whole packing pressure technique, and then to solve the key problem – interface electric spark puncture, which would...

15kv Rated Cable Spacer

It is mainly used to restrict the relative motion between sub-wires on the overhead line with 15KV voltage, so that they can maintain a certain relative interval between the electrical products.Its main material is high density polyethylene (HDPE), I...

Drop Out Fuse Cutout Thc-33

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) THC1-33/100 33-36 100 8000 170 70 720 12.5 66X37.5X14 THC1-33/200 33-36 200 1000...

12kv Enclosed Cylindrical Cutout

Composite Suspension Insulator

Main technical parameters TYPE RATED VOLTAGE(KV) RATED MECHANICAL LOAD(KN) H(MM) STRUCTURE HEIGHT H INSULATING DISTANCE (MM) MIN NORMINAL CREEPAGE DISTANCE DIAMETER OF SHED 1min POWER FREQUENCY WET WITHSTAND VOLTAGE(KV) FULL WAVE LIGHTNING IMPULS...

Composite Line Post Insulator

Composite Line Post Insulator

Drop Out Fuse Cutout Thc-30

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) THC1-30/100 30-33 100 8000 170 70 700 10.5 59x36x13.5 THC1-30/200 30-33 200 1000...

Drop Out Fuse Cutout Hthc 33-36kv

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) HTHC1-33/100 33-36 100 8000 170 70 740 4.4 61.5X38X11.5 HTHC1-33/200 33-36 200 1...

Drop Out Fuse Cutout Hthc 24-27kv

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) HTHC1-24/100 24-27 100 8000 150 65 540 4.0 50.5x38x10.5 HTHC1-24/200 24-27 200 1...

Drop Out Fuse Cutout Hthc 15-24kv

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) HTHC1-15/100 15-24 100 8000 125 45 450 3.7 45X37.5X10.5 HTHC1-15/200 25-24 200 1...

Drop Out Fuse Cutout Hthc 15-24kv

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) HTHC1-15/100 15-24 100 8000 125 45 450 3.7 45X37.5X10.5 HTHC1-15/200 25-24 200 1...

KDrop Out Fuse Cutout Hthc 12-15kv

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) HTHC1-12/100 12-15 100 8000 110 40 380 3.7 41.5X37.5X10.5 HTHC1-12/200 12-15 200...

Drop Out Fuse Cutout Thc1-30

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) THC1-30/100 30-33 100 8000 170 70 700 10.50 59X36X13.5 THC1-30/200 30-33 200 100...

Drop Out Fuse Cutout Thc1-24

Type Rated Voltage (KV) Rate Current (A) Breaking Current (A) Impulse Voltage (k V) Power frequeny withstand voltage (KV) Creepage Distance (mm) THC1-24/100A 24-27 100 8000 150 65 480 THC1-24/200A 24-27 200 10000 150 65 480

Drop Out Fuse Cutout Thc1-12kv

TYPE Rated Voltage (KV ) Rated Current(A) Breaking Current (A) Impulse Voltage (KV) Power-frequeny withstand voltage (kv) Creepage Distance (mm) Weight (kg) THC1-12/100A 12-15 100 8000 110 40 220 5.5 THC1-12/200A 12-15 200 10000 110 40 220 6

33kv Cable Spacer

Rh-B Series High Voltage Disconnector Switch

Gw9b Hv Switch Disconnect

Gw1 Series Outdoor High Voltage Isolator Switch

Strain Stay Insulator

MAIN DIMENSIONS AND STANDARD PARTICULARS Class ANSI Class Fig. NO Leakage Distance(mm) Mechanical Failing Load(kg) Power-Frequency Flashover Voltage(KV) Weight(kg) Dry Wet 54-1 904 1 41/1 ’’ 4536/10000 25 12 0.5 54-2 905 2 47.6/1 " 5443/12000 30 15 0...

Spool Type Porcelain Insulator

Glass Insulator (Standard Profile)

Glass Insulator (Fog Profile)

Composite Pin Insulator

Gw9 Series Outdoor High Voltage Isolator Switch

Polymer Pin Insulator 36kv

Composite Insulator are made of glassfiber epoxy core rod, silicone rubber shed and metal fittings. The silicon rubber shed adopt the whole packing pressure technique, and then to solve the key problem – interface electric spark puncture, which would...

15kv Rated Cable Spacer

It is mainly used to restrict the relative motion between sub-wires on the overhead line with 15KV voltage, so that they can maintain a certain relative interval between the electrical products.Its main material is high density polyethylene (HDPE), I...

Drop Out Fuse Cutout Thc-33

Type Rated Voltage (KV) Rated Current (A) Breaking current (A) Impulse voltage (KV) Power-Frequeny withstand voltage(KV) Creepage Distance (mm) Weight(KG) Dimension (cm) THC1-33/100 33-36 100 8000 170 70 720 12.5 66X37.5X14 THC1-33/200 33-36 200 1000...

12kv Enclosed Cylindrical Cutout